Sign In | Join Free | My fazendomedia.com
China Yueqing Kampa Electric Co., Ltd. logo
Yueqing Kampa Electric Co., Ltd.
Yueqing Kampa Electric Co., Ltd.
Active Member

4 Years

Home > Temperature Controller >

PID temperature controller CD101 48*48 0-400C temperature regulator

Yueqing Kampa Electric Co., Ltd.
Contact Now

PID temperature controller CD101 48*48 0-400C temperature regulator

Warranty : 1year

Customized support : OEM

Place of Origin : Zhejiang, China

Brand Name : Kampa

Model Number : CD101

Product name : Household light weight mould temperature controller factory

Theory : temperature controller

Accuracy : 1.5%

Control output : relay contact point :AC 250V 3A

Logical voltage : DC 0/5V

Power output : DC 24V

Start pulse over zero : optical couple control silicon output

Alarm way : 1Z alarm, 2Z alarm

Transmitter output : 0-10mA,4-20mA,0-5V,1-5V

Work power : AC 85-264V

Packaging Details : Normal export package or as customers' requirements

Port : Ningbo/Shanghai

Supply Ability : 100000 Piece/Pieces per Month

MOQ : 100 Pieces

Price : $8.28 - $13.00/Pieces

Contact Now

PID temperature controller CD101 48*48 0-400C temperature regulator

Technical Data

1.Outline dimension See the outline dimension picture
2.Control Mode F:PID operation and auto calculating (reverse operation) D:PID operation and auto calculating(Forward operation)
W:eating/cooling PID operation and auto calculating(cooling water)*1 A:heating/cooling PID operation and auto calculating(cooling water)*1
3.Input mode Refer to Input Range Table
4.Range Code Refer to Input Range Table
5.First control
output(OUT1)
(Heating side)
M: Relay contact output
V: Voltage impulse output
T: Thyratron output
8: Current output(IC4-20mA)
G: Thyratron driving & triggering output
6.Second control
output( OUT2)
(Cooling side)*2
No mark: when the control mode is F or D
M: Relay contact output
V: Voltage impulse output
T: Thyratron output
8: Current output(IC 4-20mA)
7.First alarm(ALM1)
8.Second alarm (ALM2)*2
N: no alarm
A: Upper-limit bias alarm
B: Lower-limit bias alarm
C: Upper/lower limit bias alarm
D: alarm in area
E: Standby upper-limit bias alarm attached
F: Standby lower-limit bias alarm attached
G: Standby upper/lower limit bias alarm
H: Upper-limit input value alarm
J: lower-limit input alarm
K: Standby upper-limit input alarm attached
L: Standby lower-limit input alarm attached
P: Heater breakage alarm(CTL-6)*3
S: Heater breakage alarm(CTL-12)*3
R: Control line breakage alarm *4
V: Upper-limit set value alarm
W: Lower-limit set value alarm
9.Communication*5 N:No communication 5:RS-485(two-wire system)
10.Water-proof/dust-proof N:no water-proof/dust-proof 1:with water-proof/dust-proof

PID temperature controller CD101 48*48 0-400C temperature regulatorPID temperature controller CD101 48*48 0-400C temperature regulatorPID temperature controller CD101 48*48 0-400C temperature regulatorPID temperature controller CD101 48*48 0-400C temperature regulatorPID temperature controller CD101 48*48 0-400C temperature regulatorPID temperature controller CD101 48*48 0-400C temperature regulator


Best PID temperature controller CD101 48*48 0-400C temperature regulator wholesale

PID temperature controller CD101 48*48 0-400C temperature regulator Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Yueqing Kampa Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)